Facebook Linkedin
The CULTEC Contactor and Recharger chambers replace conventional stormwater management systems such as ponds, swales, pipe and stone trenches or beds, or concrete structures. The chambers may be used for drywells. They may be installed in trench or bed configurations according to site restrictions or client preference. Contact area is maximized by the fully open bottoms and perforated sidewalls. The chambers are typically installed subsurface beneath parking areas to capitalize on use of space, however, they may also be placed in grassy areas.

CULTEC offers the largest variety of chamber sizes and therefore is able to accommodate almost any site parameter whether it is big or small.

Sizes range from 8.5” to 48” tall. Chamber storage capacities range from 0.819 ft³/ft to 17.66 ft³/ft.

System benefits include:
      Maximum use of land area
      Ability to recharge water on-site
      Less heavy equipment required
      Overlapping rib connection is fast and easy to install
      Repeating support panel adds to strength of installation
      Chemically resistant
      Sub-surface installation cuts down on insurance liabilities and potential breeding grounds for infectious mosquitoes
      Ability to stack units for trouble-free stockpiling on jobsite and shipping

CULTEC’s Recharger series are higher profile, larger capacity chambers. Typical CULTEC stormwater systems are designed by using the largest chamber that meets the site’s depth constraint. By doing so you reduce the number of chambers and land area required. You maximize storage volume at the given workable elevations.

CULTEC’s low profile Contactor series can accommodate systems with high water tables or other depth restraints. The lower profile units may also be used when a larger infiltrative surface area is required by design

CULTEC chambers may be installed in multiple layers to accommodate tight site constraints. The Contactor Chamber series consists of lower profile, lower capacity chambers and are typically used for installations with depth restrictions or when a larger infiltrative area is required. Conventional manifolds must be used with all models in this series except the Contactor 100HD. The Contactor 100HD has the side portal internal manifold option.

The Recharger series consists of higher profile, higher capacity chambers. When using this series, less chambers are required resulting in less labor and a smaller installation area.
Heavy Duty (HD) versions must be used for traffic applications.

Our most popular and cost-effective models used for stormwater are the 100HD, 150XLHD, 280HD, 330XLHD, & V8HD. Other models are available but not listed. Please contact our Technical Department at 203-775-4416 if the models listed below do not fit your parameters.
1 - 7 of 7 | Results Per Page | View | Unit of Measure

Model #

Model Name




Installed Length

Chamber Storage

Compatible End Cap

100HD N/A Contactor® 100HD N/A 8.00 ft2.44 m N/A 36 in914 mm N/A 12.50 in318 mm N/A 7.50 ft2.29 m N/A 1.87 ft³/ft14.00 ft³/unit105 gal0.17 m³/m0.40 m³/unit396.88 L N/A
150XLHD N/A Recharger® 150XLHD N/A 11 ft3.35 m N/A 33 in838 mm N/A 18.50 in470 mm N/A 10.25 ft3.12 m N/A 2.650 ft³/ft27.16 ft³/unit203 gal0.25 m³/m0.77 m³/unit769.12 L N/A
280HD N/A Recharger® 280HD N/A 8.00 ft2.44 m N/A 47 in1194 mm N/A 26.50 in673 mm N/A 7.00 ft2.13 m N/A 6.079 ft³/ft42.55 ft³/unit318 gal0.56 m³/m1.21 m³/unit1204.91 L N/A
330XLHD N/A Recharger® 330XLHD N/A 8.50 ft2.59 m N/A 52 in1321 mm N/A 30.50 in775 mm N/A 7.00 ft2.13 m N/A 7.459 ft³/ft52.21 ft³/unit391 gal0.69 m³/m1.48 m³/unit1478.44 L N/A
V8HD N/A Recharger® V8HD N/A N/A N/A N/A N/A N/A
902HD N/A Recharger® 902HD N/A 4.1 ft1.25 m N/A 78 in1981 mm N/A 48 in1219 mm N/A 3.67 ft1.12 m N/A 17.66 ft³/ft64.75 ft³/unit1.64 m³/m1.84 m³/unit N/A Recharger 902HD End Cap
902HD EC N/A Recharger® 902HD End Cap N/A 0.81 ft0.25 m N/A 78 in1982 mm N/A 48.5 in1231 mm N/A 0.52 ft0.16 m N/A 5.34 ft³/ft2.76 ft³/unit0.50 m³/m0.08 m³/unit N/A
1 - 7 of 7 | Results Per Page | View | Unit of Measure